460. A blasting line shall:
(1)  be distinguished from other cables and wires by its color or the presence of a rib on the outer sheath;
(2)  be used only for blasting;
(3)  be constituted for its entire length of 2 conductors isolated from each other and from the ground;
(4)  be arranged so as not to come into contact with:
(a)  an electrical power line or communication line;
(b)  a metal pipe, rail or other conductive equipment;
(5)  be disconnected from the main circuit when it enters a location such as a tunnel, a sub-level or an abandoned sector of the mine;
(6)  be checked to ensure its conductivity and for that purpose, the use of an electric detonator is prohibited.
O.C. 213-93, s. 460; O.C. 42-2004, s. 28; O.C. 1190-2010, s. 17.